Panasonic UK Price List 2024 LR - Flipbook - Page 62
GENERAL INDEX
VRF - ECOi EX Series
2-Pipe ECOi EX ME2 Series space saving
model combination from 22 to 80 HP
Outdoor unit
3ph
22 HP
24 HP
26 HP
28 HP
30 HP
32 HP
34 HP
36 HP
38 HP
40 HP
42 HP
44 HP
46 HP
48 HP
50 HP
52 HP
54 HP
56 HP
58 HP
60 HP
62 HP
64 HP
66 HP
68 HP
70 HP
72 HP
74 HP
76 HP
78 HP
80 HP
Nominal capacity
Cooling
Heating
kW
kW
61,5
69,0
68,0
76,5
73,0
81,5
78,5
87,5
85,0
95,0
90,0
100,0
96,0
108,0
101,0
113,0
107,0
119,0
113,0
127,0
118,0
132,0
124,0
138,0
130,0
145,0
135,0
150,0
140,0
155,0
145,0
160,0
151,0
169,0
156,0
175,0
162,0
182,0
168,0
189,0
174,0
195,0
180,0
201,0
185,0
207,0
190,0
213,0
196,0
219,0
202,0
226,0
208,0
233,0
213,0
239,0
219,0
245,0
224,0
252,0
U-10ME2E8 + U-12ME2E8
U-12ME2E8 + U-12ME2E8
U-10ME2E8 + U-16ME2E8
U-12ME2E8 + U-16ME2E8
U-14ME2E8 + U-16ME2E8
U-16ME2E8 + U-16ME2E8
U-14ME2E8 + U-20ME2E8
U-16ME2E8 + U-20ME2E8
U-18ME2E8 + U-20ME2E8
U-20ME2E8 + U-20ME2E8
U-10ME2E8 + U-16ME2E8 + U-16ME2E8
U-12ME2E8 + U-16ME2E8 + U-16ME2E8
U-14ME2E8 + U-16ME2E8 + U-16ME2E8
U-16ME2E8 + U-16ME2E8 + U-16ME2E8
U-14ME2E8 + U-16ME2E8 + U-20ME2E8
U-16ME2E8 + U-16ME2E8 + U-20ME2E8
U-14ME2E8 + U-20ME2E8 + U-20ME2E8
U-16ME2E8 + U-20ME2E8 + U-20ME2E8
U-18ME2E8 + U-20ME2E8 + U-20ME2E8
U-20ME2E8 + U-20ME2E8 + U-20ME2E8
U-14ME2E8 + U-16ME2E8 + U-16ME2E8 + U-16ME2E8
U-16ME2E8 + U-16ME2E8 + U-16ME2E8 + U-16ME2E8
U-10ME2E8 + U-16ME2E8 + U-20ME2E8 + U-20ME2E8
U-12ME2E8 + U-16ME2E8 + U-20ME2E8 + U-20ME2E8
U-10ME2E8 + U-20ME2E8 + U-20ME2E8 + U-20ME2E8
U-16ME2E8 + U-16ME2E8 + U-20ME2E8 + U-20ME2E8
U-16ME2E8 + U-18ME2E8 + U-20ME2E8 + U-20ME2E8
U-16ME2E8 + U-20ME2E8 + U-20ME2E8 + U-20ME2E8
U-18ME2E8 + U-20ME2E8 + U-20ME2E8 + U-20ME2E8
U-20ME2E8 + U-20ME2E8 + U-20ME2E8 + U-20ME2E8
SEER 1)
SCOP 1)
6,90
6,86
6,62
6,60
6,88
6,55
7,21
6,86
7,32
7,16
6,57
6,60
6,70
6,55
6,96
6,72
7,16
6,92
7,30
7,16
6,68
6,55
6,92
6,91
7,09
6,86
7,03
7,01
7,18
7,16
4,53
4,78
4,16
4,29
4,13
4,09
4,14
4,06
4,14
4,13
4,11
4,21
4,12
4,09
4,08
4,05
4,13
4,07
4,13
4,13
4,11
4,09
4,11
4,17
4,13
4,06
4,12
4,07
4,13
4,13
Dimension
HxWxD
mm
1 842 x 2 010 x 1 000
1 842 x 2 420 x 1 000
1 842 x 2 010 x 1 000
1 842 x 2 420 x 1 000
1 842 x 2 420 x 1 000
1 842 x 2 420 x 1 000
1 842 x 2 780 x 1 000
1 842 x 2 780 x 1 000
1 842 x 3 140 x 1 000
1 842 x 3 140 x 1 000
1 842 x 3 250 x 1 000
1 842 x 3 660 x 1 000
1 842 x 3 660 x 1 000
1 842 x 3 660 x 1 000
1 842 x 4 020 x 1 000
1 842 x 4 020 x 1 000
1 842 x 4 380 x 1 000
1 842 x 4 380 x 1 000
1 842 x 4 740 x 1 000
1 842 x 4 740 x 1 000
1 842 x 4 900 x 1 000
1 842 x 4 900 x 1 000
1 842 x 5 210 x 1 000
1 842 x 5 620 x 1 000
1 842 x 5 570 x 1 000
1 842 x 5 620 x 1 000
1 842 x 5 980 x 1 000
1 842 x 5 980 x 1 000
1 842 x 6 340 x 1 000
1 842 x 6 340 x 1 000
Weight
RRP
kg
480
540
525
585
630
630
690
690
750
750
840
900
945
945
1 005
1 005
1 065
1 065
1 125
1 125
1 260
1 260
1 275
1 335
1 335
1 380
1 440
1 440
1 500
1 500
£
20,470
22,316
22,897
24,743
26,156
27,170
28,964
29,978
31,995
32,786
36,482
38,328
39,741
40,755
42,549
43,563
45,357
46,371
48,388
49,179
53,326
54,340
55,683
57,529
58,491
59,956
61,393
62,764
64,781
65,572
Piping information
Outdoor unit
Piping diameter (liquid)
Piping diameter (gas)
Piping diameter (balance)
HP
Inch
Inch
Inch
22
⅝/¾
1⅛ / 1¼
¼
24
⅝/¾
1⅛ / 1¼
¼
26
¾/⅞
1¼ / 1½
¼
28
¾/⅞
1¼ / 1½
¼
30
¾/⅞
1¼ / 1½
¼
32
¾/⅞
1¼ / 1½
¼
34
¾/⅞
1¼ / 1½
¼
36
¾/⅞
1½ / 1⅝
¼
38
¾/⅞
1½ / 1⅝
¼
40
¾/⅞
1½ / 1⅝
¼
42
¾/⅞
1½ / 1⅝
¼
44
¾/⅞
1½ / 1⅝
¼
46
¾/⅞
1½ / 1⅝
¼
48
¾/⅞
1½ / 1⅝
¼
50
¾/⅞
1½ / 1⅝
¼
Outdoor unit
Piping diameter (liquid)
Piping diameter (gas)
Piping diameter (balance)
HP
Inch
Inch
Inch
52
¾/⅞
1½ / 1⅝
¼
54
¾/⅞
1½ / 1⅝
¼
56
¾/⅞
1½ / 1⅝
¼
58
¾/⅞
1½ / 1⅝
¼
60
¾/⅞
1½ / 1⅝
¼
62
¾/⅞
1⅝ / 1¾
¼
64
¾/⅞
1⅝ / 1¾
¼
66
¾/⅞
1⅝ / 1¾
¼
68
⅞ / 1⅛
1⅝ / 1¾
¼
70
⅞ / 1⅛
1⅝ / 1¾
¼
72
⅞ / 1⅛
1¾ / 2⅛
¼
74
⅞ / 1⅛
1¾ / 2⅛
¼
76
⅞ / 1⅛
1¾ / 2⅛
¼
78
⅞ / 1⅛
1¾ / 2⅛
¼
80
⅞ / 1⅛
1¾ / 2⅛
¼
w
pump
w/o
pump
Outdoor
£
£
£
1) SEER / SCOP is calculated based on the seasonal space cooling / heating efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF.
ECOi 2-Pipe with water heat exchanger for chilled and hot water production
Flexible modularity from 25 kW.
Maximum hot water outlet temperature: 45 °C.
Minimum chilled water outlet temperature: 5 °C.
Hydrokit
Outdoor unit
Nominal
capacity
With A class
water pump
25 kW
Without pump
PAW-250WP5G1 PAW-250W5G1
Energy
efficiency
class at
35 °C 1)
ηs,h
Dimension / Weight
(LOT21) 2) (with pump)
HxWxD
PAW-500WP5G1 PAW-500W5G1
HxWxD
Cool
Heat
kW
kW
mm / kg
mm / kg
28,0
152,00%
1 000 x 575 x 1 110 /
135 (140)
U-10ME2E8
1 842 x 770 x 1 000 /
210
13,724 13,038
152,00%
1 000 x 575 x 1 110 /
155 (165)
U-20ME2E8
1 842 x 1 540 x 1 000 /
375
14,514 13,789
25,0
A++
1ph
50 kW
RRP
Dimension / Weight
50,0
56,0
A++
Piping information
Electrical information (power supply to indoor)
Outdoor unit
kW
25
50
Piping diameter (liquid - gas)
Inch
⅜-⅞
⅝ - 1⅛
Outdoor unit
kW
25
Three phase
50
Elevation difference (in / out)
m
50 (OU above) 35 (OU below)
50 (OU above) 35 (OU below)
Recommended fuse
A
16
16
Pre-charged pipe length
m
0