Panasonic UK Price List 2024 LR - Flipbook - Page 59
VRF SYSTEMS
VRF SYSTEMS INDEX
Mini VRF - Mini ECOi LE Series R410A
Mini ECOi LE2 Series high efficiency 4 to 6 HP · R410A
Ideal solution for the limited installation space.
Wide operation range from -20 °C in heating to +46 °C in cooling.
Outdoor unit
Nominal capacity
ErP data 1)
Cooling
4 HP
1ph
3ph
U-4LE2E5
Heating
kW
kW
12,1
12,5
Dimension
SEER 2) / ηs,c
SCOP 2) / ηs,h
7,85 / 311,0%
4,87 / 191,8%
Weight
RRP
HxWxD
£
mm
kg
996 x 980 x 370
106
4,006
5 HP
U-5LE2E5
14,0
16,0
7,48 / 296,2%
4,40 / 172,9%
996 x 980 x 370
106
4,293
6 HP
U-6LE2E5
15,5
16,5
7,25 / 286,8%
4,24 / 166,7%
996 x 980 x 370
106
4,759
4 HP
U-4LE2E8
12,1
12,5
7,85 / 311,0%
4,87 / 191,8%
996 x 980 x 370
106
4,290
5 HP
U-5LE2E8
14,0
16,0
7,48 / 296,2%
4,40 / 172,9%
996 x 980 x 370
106
4,852
6 HP
U-6LE2E8
15,5
16,5
7,25 / 286,8%
4,24 / 166,7%
996 x 980 x 370
106
5,223
Piping information
Electrical information (power supply to indoor)
Outdoor unit
HP
4
5
6
Piping diameter (liquid - gas)
Inch
⅜-⅝
⅜-⅝
⅜-⅝
Outdoor unit
HP
Single phase
4
5
6
Three phase
4
5
6
Maximum piping length (total)
m
150 (180)
150 (180)
150 (180)
Recommended fuse
A
20
25
30
10
16
16
Elevation difference (in / out)
m
50 (OU above) /
40 (OU below)
50 (OU above) /
40 (OU below)
50 (OU above) /
40 (OU below)
1) SEER / SCOP and ηs,c / ηs,h are in accordance with ErP test data for F2 type variable static pressure hide-away indoor units. Eurovent certified. 2) SEER / SCOP is calculated based on the seasonal space
cooling / heating efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF.
Mini ECOi LE1 Series high efficiency 8 and 10 HP · R410A
Ideal solution for the limited installation space.
Wide operation range from -20 °C in heating to +46 °C in cooling.
Outdoor unit
3ph
Nominal capacity
Cooling
Heating
ErP data 1)
SEER 2) / ηs,c
SCOP 2) / ηs,h
HxWxD
Dimension
Weight
RRP
£
kW
kW
mm
kg
8 HP
U-8LE1E8
22,4
25,0
6,27 / 247,9%
4,24 / 166,4%
1 500 x 980 x 370
132
6,805
10 HP
U-10LE1E8
28,0
28,0
6,37 / 251,8%
4,31 / 169,5%
1 500 x 980 x 370
133
7,463
Piping information
Electrical information (power supply to indoor)
Outdoor unit
HP
8
10
Piping diameter (liquid - gas)
Inch
⅜ 3) / ½ 4) - ¾ 3) / ⅞ 4)
⅜ 3) / ½ 4) - ⅞ 3) / 1 1/8 4)
Outdoor unit
HP
Three phase
8
10
Maximum piping length (total)
m
7,5 ~ 150 (7,5 ~ 300)
7,5 ~ 150 (7,5 ~ 300)
Recommended fuse
A
16
20
Elevation difference (in / out)
m
50 (OU above) /
40 (OU below)
50 (OU above) /
40 (OU below)
1) SEER / SCOP and ηs,c / ηs,h are in accordance with ErP test data for F2 type variable static pressure hide-away indoor units. Eurovent certified. 2) SEER / SCOP is calculated based on the seasonal space
cooling / heating efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF. 3) Under 90 m for ultimate indoor unit. 4) Over 90 m for ultimate indoor unit. If the
longest piping equivalent length exceeds 90 m, increase the sizes of the main tubes by 1 rank for gas and liquid pipes.
Panasonic DX PRO Designer.
The Panasonic DX PRO Designer will be rebuilt
with an improved user experience. The software
runs in the cloud and is always up to date with the
latest products. An intuitive interface supports the
most complicated designs, allows online sharing
and project collaboration with multilingual
support.
Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
59