Panasonic UK Price List 2024 LR - Flipbook - Page 42
GENERAL INDEX
PACi NX Series
PACi NX Series Elite adaptive ducted unit - PF3 · R32
2 installation possibilities (horizontal / vertical) with high ESP 150 Pa.
nanoe™ X (Generator Mark 2).
Operation range up to 52 °C 1) in cooling and down to -20 °C in heating.
Kit (CZ-RTC5B remote controller 165£ included)
Nominal capacity
Cool
Heat
UK Total
/ at
-7 °C
SCOP /
ηs,h 2)
Outdoor unit
RRP
Dimension / Weight
Dimension / Weight
HxWxD
HxWxD
mm / kg
£
kW
kW
kW
kW
3.6 kW
KIT-36PF3ZH5
3.6
3.5 / 2.4
4.0
4.5 / 3.9
6.8 A++
4.5 A+
S-3650PF3E
250 x 800 x 730 / 25
U-36PZH3E5
695 x 875 x 320 / 42
2,382
5.0 kW
KIT-50PF3ZH5
5.0
4.9 / 3.2
5.6
5.8 / 5.0
6.1 A++
4.2 A+
S-3650PF3E
250 x 800 x 730 / 25
U-50PZH3E5
695 x 875 x 320 / 42
2,598
6.0 kW
KIT-60PF3ZH5
5.7
5.6 / 3.7
7.0
7.2 / 6.2
7.1 A++
4.4 A+
S-6071PF3E
250 x 1 000 x 730 / 30
U-60PZH3E5
695 x 875 x 320 / 43
2,992
KIT-71PF3ZH45
6.8
7.1 / 5.5
7.5
8.0 / 6.8
7.1 A++
4.7 A++
S-6071PF3E
250 x 1 000 x 730 / 30
U-71PZH4E5
996 x 980 x 370 / 66
3,499
10.0 kW
KIT-100PF3ZH45
9.5
10.2 / 8.2
10.8
11.9 / 9.8
7.4 A++
4.3 A+
S-1014PF3E
250 x 1 400 x 730 / 39
U-100PZH4E5
996 x 980 x 370 / 84
4,395
12.5 kW
KIT-125PF3ZH45
12.1
12.1 / 9.3
13.5
13.6 / 11.4 281.7%
165.0%
S-1014PF3E
250 x 1 400 x 730 / 39
U-125PZH4E5
996 x 980 x 370 / 86
4,712
14.0 kW
KIT-140PF3ZH45
13.4
13.7 / 10.1 15.5
15.4 / 12.9 275.9%
162.6%
S-1014PF3E
250 x 1 400 x 730 / 39
U-140PZH4E5
996 x 980 x 370 / 86
5,222
7.1 kW
KIT-71PF3ZH48
6.8
7.1 / 5.5
7.5
8.0 / 6.8
7.1 A++
4.7 A++
S-6071PF3E
250 x 1 000 x 730 / 30
U-71PZH4E8
996 x 980 x 370 / 82
3,560
10.0 kW
KIT-100PF3ZH48
9.5
10.2 / 8.2
10.8
11.9 / 9.8
7.4 A++
4.5 A+
S-1014PF3E
250 x 1 400 x 730 / 39
U-100PZH4E8
996 x 980 x 370 / 84
4,437
12.5 kW
KIT-125PF3ZH48
12.1
12.1 / 9.3
13.5
13.6 / 11.4 281.0%
165.0%
S-1014PF3E
250 x 1 400 x 730 / 39
U-125PZH4E8
996 x 980 x 370 / 84
4,847
14.0 kW
KIT-140PF3ZH48
13.4
13.7 / 10.1 15.5
15.4 / 12.9 275.2%
162.6%
S-1014PF3E
250 x 1 400 x 730 / 39
U-140PZH4E8
996 x 980 x 370 / 84
5,591
1ph 7.1 kW
3ph
UK
Total /
Sensible
Indoor unit
SEER /
ηs,c 2)
Piping information
mm / kg
Electrical information (power supply to outdoor)
Kit
kW
3,6
5,0
6,0
7,1
10,0
12,5
14,0
Piping diameter (liquid - gas)
Inch
¼-½ ¼-½ ¼-½ ⅜-⅝ ⅜-⅝ ⅜-⅝ ⅜-⅝
Kit
kW
3,6 5,0 6,0 7,1 10,0 12,5 14,0 7,1 10,0 12,5 14,0
Pipe length range
m
3 ~ 40 3 ~ 40 3 ~ 40 5 ~ 60 5~100 5~100 5~100
Recommended fuse
A
20
Elevation difference (in / out) 3) m
15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30
Connection in. / out.
mm² 4x1,5
Pre-charged pipe length
m
30
30
30
30
30
30
30
Additional gas amount
g/m
15
15
15
30
40
40
40
Single phase
20
25
Three phase
25
35
40
40
16
4x2,5
16
16
16
4x2,5
1) For models U-***PZH4E5(8). 2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the ηs,c / ηs,h values is
calculated based on EN 14825. 3) Outdoor unit located lower / outdoor unit located higher.
PACi NX Series Standard adaptive ducted unit - PF3 · R32
2 installation possibilities (horizontal / vertical) with high ESP
150 Pa. nanoe™ X (Generator Mark 2).
Operation range up to 43 °C in cooling and down to -15 °C in
heating.
Kit (CZ-RTC5B remote controller 165 £ included)
Nominal capacity
Cool
UK
Total /
Sensible
Indoor unit
Heat
UK Total
/ at
-7 °C
SEER /
ηs,c 1)
SCOP /
ηs,h 1)
6.0 A+
4.0 A+
kW
kW
kW
kW
3.6 kW
KIT-36PF3Z5
3.4
3.2 / 2.3
3.4
4.0 / 3.2
5.0 kW
KIT-50PF3Z5
5.0
4.8 / 3.1
5.0
5.2/4.3
6.5 A++
6.0 kW
KIT-60PF3Z5
5.7
5.6 / 3.7
5.7
6.3 / 5.4
6.4 A++
1ph 7.1 kW
KIT-71PF3Z5
6.8
6.5 / 4.2
6.8
7.1 / 5.8
6.0 A+
10.0 kW
KIT-100PF3Z5
9.5
10.6 / 7.3
9.5
12.5 kW
KIT-125PF3Z5
12.1
12.6 / 8.2
14.0 kW
KIT-140PF3Z5
13.4
10.0 kW
KIT-100PF3Z8
3ph 12.5 kW
14.0 kW
Outdoor unit
RRP
Dimension / Weight
Dimension / Weight
HxWxD
HxWxD
mm / kg
£
mm / kg
S-3650PF3E
250 x 800 x 730 / 25
U-36PZ3E5
619 x 824 x 299 / 32
1,994
4.0 A+
S-3650PF3E
250 x 800 x 730 / 25
U-50PZ3E5
619 x 824 x 299 / 35
2,250
4.4 A+
S-6071PF3E
250 x 1 000 x 730 / 30
U-60PZ3E5A
695 x 875 x 320 / 42
2,495
4.1 A+
S-6071PF3E
250 x 1 000 x 730 / 30
U-71PZ3E5A
695 x 875 x 320 / 50
2,830
12.5 / 11.3 6.6 A++
3.9 A
S-1014PF3E
250 x 1 400 x 730 / 39
U-100PZ3E5
996 x 980 x 370 / 83
3,497
12.1
14.7 / 14.5 257.4%
142.6%
S-1014PF3E
250 x 1 400 x 730 / 39
U-125PZ3E5
996 x 980 x 370 / 87
3,844
13.9 / 9.0
13.4
15.4 / 14.7 252.2%
140.6%
S-1014PF3E
250 x 1 400 x 730 / 39
U-140PZ3E5
996 x 980 x 370 / 87
4,552
9.5
10.6 / 7.3
9.5
12.5 / 11.3 6.5 A++
3.9 A
S-1014PF3E
250 x 1 400 x 730 / 39
U-100PZ3E8
996 x 980 x 370 / 83
3,607
KIT-125PF3Z8
12.1
12.6 / 8.2
12.1
14.7 / 14.5 256.2%
142.6%
S-1014PF3E
250 x 1 400 x 730 / 39
U-125PZ3E8
996 x 980 x 370 / 87
3,911
KIT-140PF3Z8
13.4
13.9 / 9.0
13.4
15.4 / 14.7 251.4%
140.6%
S-1014PF3E
250 x 1 400 x 730 / 39
U-140PZ3E8
996 x 980 x 370 / 87
4,587
Piping information
Electrical information (power supply to outdoor)
Kit
kW
3,6
5,0
6,0
7,1
10,0
12,5
14,0
Piping diameter (liquid - gas)
Inch
¼-½ ¼-½ ¼-½ ¼-⅝ ⅜-⅝ ⅜-⅝ ⅜-⅝
Kit
kW
3,6
5,0
6,0
7,1
10,0 12,5 14,0 10,0 12,5 14,0
Pipe length range
m
3 ~ 15 3 ~ 20 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 50 5 ~ 50
Recommended fuse
A
20
20
25
25
35
Elevation difference (in / out) 2) m
15 / 15 15 / 15 15 / 30 20 / 30 15 / 30 15 / 30 15 / 30
Connection in. / out.
mm² 4x1,5
Pre-charged pipe length
m
7,5
7,5
30
30
30
30
30
Additional gas amount
g/m
10
15
15
17
45
45
45
Single phase
Three phase
4x2,5
40
40
16
16
16
4x2,5
1) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the ηs,c / ηs,h values is calculated based on EN 14825.
2) Outdoor unit located lower / outdoor unit located higher.
42